Luvis S-300 with camera

The price of the product is 195.000 CZK including VAT

A modern, beautiful and very powerful operating lamp with a great price/performance ratio and complemented by a high quality camera with an impressively sharp optical zoom. It is particularly suitable for ostomy surgery, implantology or endodontics. Thanks to its 5 joints, it has excellent positioning and ergonomics.
A very popular feature is the focusing of the light beam. Switching the colour temperature and controlling the illumination intensity in the operating field up to 130,000 lx is standard. Excellent colour rendering is a matter of course. The variant with battery backup is a full-fledged main operating luminaire.

Show more

Advantages of the luminaire

Camera
Output up to 130,000 lx
Touch panel
Focusable beam
Type
S300
Type of luminaire
Auxiliary (treatment) luminaire
Surgical lamp for small surgery
Class of protection
I
Plug with protective pin
Class of medical device
I
One is the class of medical devices with the lowest risk.
Designated place
operating theatre
Suitable for minor surgical procedures or as an auxiliary luminaire.
Illuminance control
30-100 %
Smooth intensity adjustment.
Methods of control
touch panel on the head arm, touch buttons on the handle, Android app
Easy and accessible control of the luminaire mode and lighting parameters.
Mounting variants
W, M, C, D
Wall, mobile, ceiling and double ceiling mounting.
Central illuminance (Ec)
130 000 lx
The standard requires 40 000-160 000 lx. In summer, up to 100,000 lx outside, in winter about 25,000 lx
Working distance
1 m
Distance from the lamp in which the work is being done and where the parameters are specified.
Light field diameter (d10)
15-25 cm
The size of the area in which the intensity is between 10% and the maximum.
Depth of illumination
75 cm
The distance between the points above and below the centre of the working field where 60% of the maximum is.
Single-mask stoppability
-
Simulates shading of the luminaire with one head.
Dual-mask stoppability
0.5
Simulates the shading of the luminaire by two heads.
Replacement with tube
1
Simulates illumination of the cavity.
Replacement with tube and one mask
-
Simulates illuminating the cavity and shading with one head.
Replacement with tube and two masks
0.5
Simulates cavity illumination and shading with two heads.
Chromaticity temperature (Tc)
3800, 4300, 4800 K
The colour temperature can be switched to warm/neutral/cooler with the button.
Colour rendering index (Ra)
96
Values over 90 indicate good quality light.
Specific index for deep red (R9)
95
Values over 80 indicate a good quality tissue colour rendition.
Total irradiance (Ee)
455 W/m2
How much energy in total falls on the illuminated area, the maximum is 1000 W/m².
Ratio of irradiance to illuminance
3,6 mW/m²-lx
What is the irradiance per lux, the maximum is 6 mW/m²-lx
Dimensions of the head
52 x 47 cm
The size of the illuminating part of the lamp.
Lifetime of the light source
60 000 h
About seven years of continuous lighting, i.e. about 25 years in real operation.
Power input
61 W
How much electricity a lamp needs to operate is equivalent to a weak light bulb.
Power
100-240 V ~, 50/60 Hz
A normal socket.
The main standard
EN 60601-2-41
Standard for operating luminaires.
Type of luminaire (Dental mode)
Dental Work Lamp
Dental operating lamp
Designated place
dental practice
Universal lamp for dentistry and surgery.
Illuminance (Ec)
5000-30 000 lx
It is measured in the middle position of the colour temperature in the middle of the working field.
Illuminance control
16-100% (3 steps)
The intensity can be controlled with a knob or remote control.
Radiation intensity (Ee)
231 W/m2
How much total energy is incident on the illuminated area, the maximum is 350 W/m²
Illuminating the patient's eyes
≤ 1200 lux
A maximum of 1200 lx is allowed to prevent the light from shining into the patient's eyes.
A sharp shadow
12 mm
A crown coin must not cast a sharp shadow larger than 12 mm from a distance of 5 cm.
Working distance
1 m
Also known as the focal length, the parameters are specified here.
Focal pattern (d10)
15 × 9 cm
An oval-shaped pattern in which 10 percent or more of the maximum intensity is present.
Focal Pattern (d50)
10 × 6 cm
An oval-shaped pattern in which 50 percent or more of the maximum intensity is present.
Uniformity (d50/d10)
> 65 %
Ratio of maximum and average intensity in the working field.
Chromaticity temperature
4800 K
The colour temperature can be switched to warm/neutral/cooler using the buttons or the remote control.
Colour rendering index (Ra)
95
Values above 90 indicate good quality light.
The main standard
EN 9680
Standard for dental work lights.
Type of luminaire (examination)
examination luminaire
Known mainly as an examination lamp.
Designated place
Investigation room
Central illuminance (Ec)
30 000-60 000 lx
Illuminance control
50-100% (3 steps)
Working distance
1 m
Light field diameter (d10)
15 cm
Light field diameter (d50)
9 cm
Uniformity (d50/d10)
> 55 %
Chromaticity temperature (Tc)
3800, 4300, 4800 K
Colour rendering index (Ra)
96
Total irradiance (Ee)
231 W/m²
The main standard
EN 60601-2-41
Optional accessories
battery, foot switch
View Full Version
V1.0
Higher model
M210
Lower model
S200
Type
Type of luminaire
Class of protection
Class of medical device
Designated place
Illuminance control
Methods of control
Mounting variants
Central illuminance (Ec)
Working distance
Light field diameter (d10)
Depth of illumination
Single-mask stoppability
Dual-mask stoppability
Replacement with tube
Replacement with tube and one mask
Replacement with tube and two masks
Chromaticity temperature (Tc)
Colour rendering index (Ra)
Specific index for deep red (R9)
Total irradiance (Ee)
Ratio of irradiance to illuminance
Dimensions of the head
Lifetime of the light source
Power input
Power
The main standard
Type of luminaire (Dental mode)
Designated place
Illuminance (Ec)
Illuminance control
Radiation intensity (Ee)
Illuminating the patient's eyes
A sharp shadow
Working distance
Focal pattern (d10)
Focal Pattern (d50)
Uniformity (d50/d10)
Chromaticity temperature
Colour rendering index (Ra)
The main standard
Type of luminaire (examination)
Designated place
Central illuminance (Ec)
Illuminance control
Working distance
Light field diameter (d10)
Light field diameter (d50)
Uniformity (d50/d10)
Chromaticity temperature (Tc)
Colour rendering index (Ra)
Total irradiance (Ee)
The main standard
Optional accessories
View Full Version
Higher model
Lower model
S300
Auxiliary (treatment) luminaire
I
I
operating theatre
operating theatre
30-100 %
touch panel on the head arm, touch buttons on the handle, Android app
W, M, C, D
130 000 lx
1 m
15-25 cm
-
0.5
1
-
0.5
3800, 4300, 4800 K
96
95
455 W/m2
3,6 mW/m²-lx
52 x 47 cm
60 000 h
61 W
100-240 V ~, 50/60 Hz
EN 60601-2-41
Dental Work Lamp
dental practice
5000-30 000 lx
16-100% (3 steps)
231 W/m2
≤ 1200 lux
12 mm
1 m
15 × 9 cm
10 × 6 cm
> 65 %
4800 K
95
EN 9680
examination luminaire
Investigation room
30 000-60 000 lx
50-100% (3 steps)
1 m
15 cm
9 cm
> 55 %
3800, 4300, 4800 K
96
231 W/m²
EN 60601-2-41
battery, foot switch
V1.0
M210
S200
Surgical lamp for small surgery
Plug with protective pin
One is the class of medical devices with the lowest risk.
Suitable for minor surgical procedures or as an auxiliary luminaire.
Smooth intensity adjustment.
Easy and accessible control of the luminaire mode and lighting parameters.
Wall, mobile, ceiling and double ceiling mounting.
The standard requires 40 000-160 000 lx. In summer, up to 100,000 lx outside, in winter about 25,000 lx
Distance from the lamp in which the work is being done and where the parameters are specified.
The size of the area in which the intensity is between 10% and the maximum.
The distance between the points above and below the centre of the working field where 60% of the maximum is.
Simulates shading of the luminaire with one head.
Simulates the shading of the luminaire by two heads.
Simulates illumination of the cavity.
Simulates illuminating the cavity and shading with one head.
Simulates cavity illumination and shading with two heads.
The colour temperature can be switched to warm/neutral/cooler with the button.
Values over 90 indicate good quality light.
Values over 80 indicate a good quality tissue colour rendition.
How much energy in total falls on the illuminated area, the maximum is 1000 W/m².
What is the irradiance per lux, the maximum is 6 mW/m²-lx
The size of the illuminating part of the lamp.
About seven years of continuous lighting, i.e. about 25 years in real operation.
How much electricity a lamp needs to operate is equivalent to a weak light bulb.
A normal socket.
Standard for operating luminaires.
Dental operating lamp
Universal lamp for dentistry and surgery.
It is measured in the middle position of the colour temperature in the middle of the working field.
The intensity can be controlled with a knob or remote control.
How much total energy is incident on the illuminated area, the maximum is 350 W/m²
A maximum of 1200 lx is allowed to prevent the light from shining into the patient's eyes.
A crown coin must not cast a sharp shadow larger than 12 mm from a distance of 5 cm.
Also known as the focal length, the parameters are specified here.
An oval-shaped pattern in which 10 percent or more of the maximum intensity is present.
An oval-shaped pattern in which 50 percent or more of the maximum intensity is present.
Ratio of maximum and average intensity in the working field.
The colour temperature can be switched to warm/neutral/cooler using the buttons or the remote control.
Values above 90 indicate good quality light.
Standard for dental work lights.
Known mainly as an examination lamp.

Products

Similar products

Powerful operating lamp with camera...

349.000 CZK including VAT

Full-spectrum additional LED luminaire -...

5 570 CZK including VAT

Full-spectrum complementary LED luminaire - for cassette...

4 970 CZK including VAT

I'm interested

Non-binding inquiry

Name *
Surname *
E-mail *
Tel: *
Report/Contract form *

Consultation

Arrange a consultation

We use cookies

More light into this topic?

We use cookies to improve our website.

Cookies